ROI-XMA LOOP POWERED 4-20mA mV TRANSMITTER

           
   

READ SENSORS WITH YOUR PLC

Use spare PLC 4-20mA inputs for sensor measurement, with ROI-XMA mV transmitters. ROI-XMA mV transmitters allow the simple measurement of industry standard sensors. Existing sensors can be connected to modern control systems. ROI-XMA 4-20mA transmitters are a simple way to add sensor measurement to a PLC.

ROI-XMA $210.00

(excluding tax & shipping)

mV 4-20mA 2 wire loop powered transmitter

The ROI-XMA series is a versatile family of loop powered 4-20mA mV transmitters. Standard versions provided for voltage ranges between 50mV and 500mV. Signal range can be custom scaled to alternate spans from 5 mV to 1 V. Transmitter supply voltage may be from 7.5 to 36Vdc. Output circuit is reverse connection protected and filtered.

  • PLUGGABLE EURO ELECTRICAL CONNECTORS

  • SNAP ON MOUNTING BASE FOR DIN RAIL OR SURFACE MOUNTING

  • WIDE 4-20mA LOOP SUPPLY RANGE FROM 7.5-36V

  • USED IN REMOTE MONITORING

  • MEASURE INDUSTRY STANDARD mV SENSORS

  • READ TRANSMITTER WITH PLC, RTU, PC A-D SYSTEMS

  • USE WITH 20mA, 5V, 10V MEASUREMENT SYSTEMS *

Specifications:

MOUNTING: 35mm DIN rail or surface mountable snap on base

SUPPLY RANGE: 7.5 TO 36Vdc

SIGNAL OUTPUT: 4-20mA ( LOOP POWERED )**

CONNECTIONS: 30-12awg wire

INPUT RANGE: 0-50 mV

INPUT TYPE: mV sensor

INPUT IMPEDANCE: differential mode 0.1 G Ohms ||1 pf / common mode 5 G Ohms||10 pf

INPUT EXCITATION: 2.5V (@2.5mA max)

RESPONSE: 10ms

DIMENSIONS: 4.510 X 1.258 X 3.948 (height above rail) LWH***

* Loop termination resistor required when used with voltage ADC

** 4-20mA signal uses a 2 wire connection. Resistance transmitter output is connected in series, with supply and measurement device.

*** Mated connector adds additional 3/8” to height.

Use spare PLC 4-20mA inputs for mV sensor measurement, with the ROI-XMA mV sensor transmitter. ROI-XMA mV transmitters allow the simple measurement of industry standard sensors. Existing mV sensors can be connected to modern control systems. The ROI-XMA transmitter can add mV sensor measurement to a PLC.

How to Order

ROI-XMA LOOP POWERED 4-20mA mV TRANSMITTER

Download Cutsheet

     
           
Follow us on Twitter Like us on Facebook Company Contact Info      
  Made In The USA        

Robert Owen Inc.
PO Box 227
Albertson, NY 11507
Phone 516-629-5134
Fax 516-706-1705

©2015 Robert Owen Inc.